DP/DP coupler This Product Information contains important information on the manual DP/DP coupler, A5E The Product Information is part of the product supplied and the information in it should be considered more up-to-date if uncertainties arise. Integration of a module preconfigured for F-communication into the GSD. · This manual applies to the DP/DP Coupler, order no. 6ES7 ADXA0. It describes the components valid at the time of the manuals publication. Wereserve the right to enclose a product information document containing currentinformation with new components and new releases of components. Changes since the previous version. · DESCRIPTION: Station type: DP/DP Coupler, Release 3 Order no.: 6ES7 ADXA0 Version: V (03/) DP-DP-Koppler_www.doorway.ru (21 KB). Station type: DP/DP Coupler, Release 2 Order no.: 6ES7 ADXA0 Version: V (12/) DP-DP-Koppler_www.doorway.ru (21 KB). Station type: DP/DP Coupler (release B) Order no.: 6ES7 ADXA0 DP-DP .
7 posts in this topic. About a year ago we used a Siemens DP/DP-coupler (6ESADXA0) to connect two profibusnets. The CPU on both sides were Mitsubishi Q02H and a QJ71PB92D-profibus master. No problems whatsoever!! No settings - no problems. The only thing you have to make is to assign each side of the DP/DP-coupler a profibusaddress. SIMATIC DP, DP/DP coupler Coupling module for connecting of two PROFIBUS DP networks redundant current infeed TECHNICAL SUPPORT 01SALES The DP/DP coupler is configured within the hardware configurator. A GSD file or external parameterization software is not necessary. Technical specifications General information Order number AD02 Article name DP/DP coupler Scope of delivery DP/DP coupler, manual Dimensions (DxWxH) x 40 x mm Weight Approx. g PROFIBUS.
the DP/DP coupler manual is certainly a good place to start, on top of that, you'll find additional info in the FAQ's below (there's also a fair few DP/DP coupler related discussiosn to be found here on the forum just in case you have still questions afterwards): What are the special features of input/output addressing with the DP/DP coupler?. Dear All,I saw in DP-DP Coupler manual that " Maximum Length of Data Exchanged consists of bytes input data and bytes of output data, of which upto bytes are consistent".My question is Why bytes are consistent, if i need to use 2. this manual is about DP/PA Coupler, I'm using DP/DP Coupler. Anyway, looks like there is possibility, using SFC 13 DPNRM_DG, to osserve bit1 of byte24, to distinguish case of CPU of coupled network in STOP or TURNED OFFfrom all other cases of missing communication.
0コメント